Trusted B2B source for industrial electrical products

XT1/XT3 TMD/TMF

ABB Tmax XT1 and XT3 MCCBs are fixed three-pole molded case circuit breakers designed for power distribution with thermomagnetic TMD/TMF release protection. Engineered for 160–1600A applications, these breakers provide precise overload and short-circuit protection for industrial LV systems. Key features include front terminals, compact frame size, high breaking capacity, and reliable isolation performance.

TMF - Fixed thermal and fixed magnetic for power distribution

TMD - Adjustable thermal (70-100%of In) and fixed magnetic (10 x In) for power distribution
Terminal Type: Front Terminals
Mounting: Fixed Type
Standards Compliance: IEC 60947-2 

XT2/XT4/XT5/XT6 TMD/TMA - 3 Pole

ABB Tmax XT2, XT4, XT5 and XT6 3-pole molded case circuit breakers are engineered for industrial power distribution with thermomagnetic TMD/TMA release protection. Designed for 160A to 1600A applications, these MCCBs provide precise overload and short-circuit protection in low-voltage systems. Featuring fixed execution, front terminals, high breaking capacity and compact frame design, they ensure dependable isolation for MCC panels, distribution boards and heavy-duty infrastructure installations.

TMD - Adjustable thermal (70-100%of In) and fixed magnetic (10 x In) for power distribution

TMA - Adjustable thermal (70-100% of In) and adjustable magnetic (5-10 of In) for power distribution
Terminal Type: Front Terminals
Mounting: Fixed Type
Standards Compliance: IEC 60947-2


XT2/XT4/XT5/XT6 TMD/TMA - 4 Pole

ABB Tmax XT2, XT4, XT5 and XT6 3-pole molded case circuit breakers are engineered for industrial power distribution with thermomagnetic TMD/TMA release protection. Designed for 160A to 1600A applications, these MCCBs provide precise overload and short-circuit protection in low-voltage systems. Featuring fixed execution, front terminals, high breaking capacity and compact frame design, they ensure dependable isolation for MCC panels, distribution boards and heavy-duty infrastructure installations.

TMD - Adjustable thermal (70-100%of In) and fixed magnetic (10 x In) for power distribution

TMA - Adjustable thermal (70-100% of In) and adjustable magnetic (5-10 of In) for power distribution
Terminal Type: Front Terminals
Mounting: Fixed Type
Standards Compliance: IEC 60947-2

TMAX Accessory: Terminals,Seperator,Rotary Handle

ABB Tmax MCCB accessories including terminals, phase separators and rotary handles are engineered for secure installation, enhanced safety and flexible operation of Tmax molded case circuit breakers. Designed for industrial power distribution panels, these genuine ABB accessories ensure proper insulation, safe cable termination and door-mounted operation capability.

Separator Function: Phase insulation & arc containment support
Rotary Handle Type: Door-mounted / Direct-mounted options
Mounting Compatibility: XT1 / XT2 / XT3 / XT4 / XT5 / XT6 frames

Tmax XT Accessories : Service releases

ABB Tmax MCCB service releases are engineered for remote tripping and voltage-controlled protection in low-voltage power distribution systems. These release units enable enhanced safety, emergency shutdown capability and automation control.

Types Available: Shunt Trip Release (SOR) , Undervoltage Release (UVR)

Operating Voltage Options: 24V AC/DC, 48V AC/DC, 110V AC, 220–240V AC

Mounting: Internal plug-in / side-mounted

Standards Compliance: IEC 60947-2 compatible

Tmax XT Accessories : Electrical signals

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

Filter

Image
Ordering Code
poles in a breaking capacity at 415vac icu Qty Accessories Enq
XT2N 160 4P TMD/TMA 1.6A

XT2N 160 4P TMD/TMA 1.6A

4

1.6A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 2A

XT2N 160 4P TMD/TMA 2A

4

2A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 2.5A

XT2N 160 4P TMD/TMA 2.5A

4

2.5A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 3.2A

XT2N 160 4P TMD/TMA 3.2A

4

3.2A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 4A

XT2N 160 4P TMD/TMA 4A

4

4A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 5A

XT2N 160 4P TMD/TMA 5A

4

5A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 6.3A

XT2N 160 4P TMD/TMA 6.3A

4

6.3A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 8A

XT2N 160 4P TMD/TMA 8A

4

8A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 10A

XT2N 160 4P TMD/TMA 10A

4

10A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 12.5A

XT2N 160 4P TMD/TMA 12.5A

4

12.5A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 16A

XT2N 160 4P TMD/TMA 16A

4

16A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 20A

XT2N 160 4P TMD/TMA 20A

4

20A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 25A

XT2N 160 4P TMD/TMA 25A

4

25A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 32A

XT2N 160 4P TMD/TMA 32A

4

32A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 40A

XT2N 160 4P TMD/TMA 40A

4

40A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 50A

XT2N 160 4P TMD/TMA 50A

4

50A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 63A

XT2N 160 4P TMD/TMA 63A

4

63A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 80A

XT2N 160 4P TMD/TMA 80A

4

80A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 100A

XT2N 160 4P TMD/TMA 100A

4

100A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 125A

XT2N 160 4P TMD/TMA 125A

4

125A

36KA

Add to Quote
XT2N 160 4P TMD/TMA 160A

XT2N 160 4P TMD/TMA 160A

4

160A

36KA

Add to Quote
XT4N 250 4P TMD/TMA 200A

XT4N 250 4P TMD/TMA 200A

4

200A

36KA

Add to Quote
XT4N 250 4P TMD/TMA 225A

XT4N 250 4P TMD/TMA 225A

4

225A

36KA

Add to Quote
XT4N 250 4P TMD/TMA 250A

XT4N 250 4P TMD/TMA 250A

4

250A

36KA

Add to Quote
XT5N 630 4P TMD/TMA 320A

XT5N 630 4P TMD/TMA 320A

4

320A

36KA

Add to Quote
XT5N 630 4P TMD/TMA 400A

XT5N 630 4P TMD/TMA 400A

4

400A

36KA

Add to Quote
XT5N 630 4P TMD/TMA 500A

XT5N 630 4P TMD/TMA 500A

4

500A

36KA

Add to Quote
XT5N 630 4P TMD/TMA 630A

XT5N 630 4P TMD/TMA 630A

4

630A

36KA

Add to Quote
XT6N 800 4P TMD/TMA 800A

XT6N 800 4P TMD/TMA 800A

4

800A

36KA

Add to Quote
XT2S 160 4P TMD/TMA 1.6A

XT2S 160 4P TMD/TMA 1.6A

4

1.6A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 2A

XT2S 160 4P TMD/TMA 2A

4

2A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 2.5A

XT2S 160 4P TMD/TMA 2.5A

4

2.5A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 3.2A

XT2S 160 4P TMD/TMA 3.2A

4

3.2A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 4A

XT2S 160 4P TMD/TMA 4A

4

4A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 5A

XT2S 160 4P TMD/TMA 5A

4

5A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 6.3A

XT2S 160 4P TMD/TMA 6.3A

4

6.3A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 8A

XT2S 160 4P TMD/TMA 8A

4

8A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 10A

XT2S 160 4P TMD/TMA 10A

4

10A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 12.5A

XT2S 160 4P TMD/TMA 12.5A

4

12.5A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 16A

XT2S 160 4P TMD/TMA 16A

4

16A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 20A

XT2S 160 4P TMD/TMA 20A

4

20A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 25A

XT2S 160 4P TMD/TMA 25A

4

25A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 32A

XT2S 160 4P TMD/TMA 32A

4

32A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 40A

XT2S 160 4P TMD/TMA 40A

4

40A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 50A

XT2S 160 4P TMD/TMA 50A

4

50A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 63A

XT2S 160 4P TMD/TMA 63A

4

63A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 80A

XT2S 160 4P TMD/TMA 80A

4

80A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 100A

XT2S 160 4P TMD/TMA 100A

4

100A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 125A

XT2S 160 4P TMD/TMA 125A

4

125A

50kA

Add to Quote
XT2S 160 4P TMD/TMA 160A

XT2S 160 4P TMD/TMA 160A

4

160A

50kA

Add to Quote
XT4S 250 4P TMD/TMA 200A

XT4S 250 4P TMD/TMA 200A

4

200A

50kA

Add to Quote
XT4S 250 4P TMD/TMA 225A

XT4S 250 4P TMD/TMA 225A

4

225A

50kA

Add to Quote
XT4S 250 4P TMD/TMA 250A

XT4S 250 4P TMD/TMA 250A

4

250A

50kA

Add to Quote
XT5S 630 4P TMD/TMA 320A

XT5S 630 4P TMD/TMA 320A

4

320A

50kA

Add to Quote
XT5S 630 4P TMD/TMA 400A

XT5S 630 4P TMD/TMA 400A

4

400A

50kA

Add to Quote
XT5S 630 4P TMD/TMA 500A

XT5S 630 4P TMD/TMA 500A

4

500A

50kA

Add to Quote
XT5S 630 4P TMD/TMA 630A

XT5S 630 4P TMD/TMA 630A

4

630A

50KA

Add to Quote
XT6S 800 4P TMD/TMA 800A

XT6S 800 4P TMD/TMA 800A

4

800A

50KA

Add to Quote
XT2H 160 4P TMD/TMA 1.6A

XT2H 160 4P TMD/TMA 1.6A

4

1.6A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 2A

XT2H 160 4P TMD/TMA 2A

4

2A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 2.5A

XT2H 160 4P TMD/TMA 2.5A

4

2.5A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 3.2A

XT2H 160 4P TMD/TMA 3.2A

4

3.2A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 4A

XT2H 160 4P TMD/TMA 4A

4

4A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 5A

XT2H 160 4P TMD/TMA 5A

4

5A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 6.3A

XT2H 160 4P TMD/TMA 6.3A

4

6.3A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 8A

XT2H 160 4P TMD/TMA 8A

4

8A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 10A

XT2H 160 4P TMD/TMA 10A

4

10A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 12.5A

XT2H 160 4P TMD/TMA 12.5A

4

12.5A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 16A

XT2H 160 4P TMD/TMA 16A

4

16A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 20A

XT2H 160 4P TMD/TMA 20A

4

20A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 25A

XT2H 160 4P TMD/TMA 25A

4

25A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 32A

XT2H 160 4P TMD/TMA 32A

4

32A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 40A

XT2H 160 4P TMD/TMA 40A

4

40A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 50A

XT2H 160 4P TMD/TMA 50A

4

50A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 63A

XT2H 160 4P TMD/TMA 63A

4

63A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 80A

XT2H 160 4P TMD/TMA 80A

4

80A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 100A

XT2H 160 4P TMD/TMA 100A

4

100A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 125A

XT2H 160 4P TMD/TMA 125A

4

125A

70KA

Add to Quote
XT2H 160 4P TMD/TMA 160A

XT2H 160 4P TMD/TMA 160A

4

160A

70KA

Add to Quote
XT4H 250 4P TMD/TMA 200A

XT4H 250 4P TMD/TMA 200A

4

200A

70KA

Add to Quote
XT4H 250 4P TMD/TMA 225A

XT4H 250 4P TMD/TMA 225A

4

225A

70KA

Add to Quote
XT4H 250 4P TMD/TMA 250A

XT4H 250 4P TMD/TMA 250A

4

250A

70KA

Add to Quote
XT5H 630 4P TMD/TMA 320A

XT5H 630 4P TMD/TMA 320A

4

320A

70KA

Add to Quote
XT5H 630 4P TMD/TMA 400A

XT5H 630 4P TMD/TMA 400A

4

400A

70KA

Add to Quote
XT5H 630 4P TMD/TMA 500A

XT5H 630 4P TMD/TMA 500A

4

500A

70KA

Add to Quote
XT5H 630 4P TMD/TMA 630A

XT5H 630 4P TMD/TMA 630A

4

630A

70KA

Add to Quote
XT6H 800 4P TMD/TMA 800A

XT6H 800 4P TMD/TMA 800A

4

800A

70KA

Add to Quote

Additional information for XT2/XT4/XT5/XT6 TMD/TMA - 4 Pole

ABB XT2/XT4/XT5/XT6 TMD/TMA - 4 Pole FAQ 1. What is the difference between TMD and TMA release in Tmax XT MCCBs? TMD typically offers adjustable thermal and fixed magnetic protection, while TMA provides defined thermomagnetic characteristics based on frame rating. Selection depends on load profile and coordination requirements. 2. How do I select between XT2, XT4, XT5 and XT6 frames? Frame selection depends on required current rating, breaking capacity and fault level of the installation. Our team assists with short-circuit coordination and feeder sizing. 3. Are these MCCBs suitable for heavy industrial applications? Yes. XT4, XT5 and XT6 frames are widely used in manufacturing plants, process industries and infrastructure projects requiring higher fault handling 4. Do you supply for large-scale panel manufacturing projects? Yes. As an Authorized ABB Distributor in Coimbatore, we support OEM panel builders, EPC contractors and industrial buyers with bulk supply contracts. 5. Are accessories available for custom

Find Related

Enquire Now