Trusted B2B source for industrial electrical products

OESA/OS switch disconnector , DIN-type

ABB OESA and OS DIN-type switch fuse disconnectors are designed for safe load isolation and protection in low-voltage distribution systems from 32A to 800A. These SDF units are supplied complete with operating shaft and handle, with the mechanism positioned at the end of the switch fuse for efficient door-coupled operation. Built for industrial panels, they ensure reliable switching performance, high short-circuit withstand capability and secure integration in power distribution boards.

Mounting Type: Base mounting
Fuse Compatibility: NH fuse links (model dependent)
Standards Compliance: IEC 60947-3

OESA/OS switch disconnector fuse, BS-type

ABB OESA and OS BS-type switch disconnector fuse units are engineered for safe load isolation and short-circuit protection in low-voltage distribution systems from 32A to 800A supplied with shaft and handle. Designed for BS standard fuse links, these SDF units deliver reliable AC-23A load switching performance, high fault withstand capacity and robust mechanical durability.

Fuse Compatibility: BS-Type Fuse Links
Rated Operational Voltage: Up to 690V AC
Mounting: Panel Mount
Switching Mechanism: Manual Load Break
Short-Circuit Performance: High fault withstand (as per IEC rating)
Standard Compliance: IEC 60947-3

HRC fuse links and base, DIN-type

DIN-type HRC fuse links and bases from ABB deliver high breaking capacity short-circuit protection for LV distribution systems. Designed as per IEC 60269, these fuse links ensure fast fault clearing, low I²t energy let-through and thermal stability under heavy industrial loads. Suitable for motor feeders, switch fuse units and power distribution panels, ABB DIN HRC fuses feature ceramic bodies, silver-plated contacts and standardized DIN dimensions for secure installation and easy replacement.

Utilization Category: gG / aM

Body Material: High-strength ceramic

Contact Type: Silver-plated copper

Mounting: Panel-mounted DIN fuse base

Standard: IEC 60269

Application: LV power distribution & motor protection

HRC fuse links and base, BS-type

BS-type HRC fuse links and bases from ABB are engineered for high fault level industrial power distribution systems. Designed to meet British Standard dimensions, these high rupturing capacity fuse links provide precise short-circuit protection with controlled I²t energy limitation. Built with robust ceramic bodies and heavy-duty blade contacts,

Utilization Category: gG / aM
Fuse Body: Ceramic with quartz filling
Contact Type: Heavy-duty blade terminals
Mounting: Panel-mounted fuse base
Standard: IEC 60269 / BS Standard

Accessories for OESA/OS

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

LOREM IPSUM

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.

Filter

Image
Ordering Code
poles rated current fuse size Qty Accessories Enq
OESA32G2

OESA32G2

2

32 A

A2

Add to Quote
OESA63G2

OESA63G2

2

63 A

A3

Add to Quote
OESA100G2

OESA100G2

2

100 A

A4

Add to Quote
OESA125G2

OESA125G2

2

125 A

A4

Add to Quote
OESA160B2

OESA160B2

2

160 A

B2

Add to Quote
OS200B02P

OS200B02P

2

200 A

B1-B2

Add to Quote
OS250B02P

OS250B02P

2

250 A

B1-B3

Add to Quote
OS315B02P

OS315B02P

2

315 A

B1-B4

Add to Quote
OS400B02P

OS400B02P

2

400 A

B1-B4

Add to Quote
OS630B02P

OS630B02P

2

630 A

C1-C2

Add to Quote
OS800B02P

OS800B02P

2

800 A

C1-C3

Add to Quote
OS1250B02P

OS1250B02P

2

1250 A

D1

Add to Quote
OESA32G1

OESA32G1

3

32 A

A2

Add to Quote
OESA63G1

OESA63G1

3

63 A

A3

Add to Quote
OESA100G1

OESA100G1

3

100 A

A4

Add to Quote
OESA125G1

OESA125G1

3

125 A

A4

Add to Quote
OESA160B3

OESA160B3

3

160 A

B2

Add to Quote
OS200B03P

OS200B03P

3

200 A

B1-B2

Add to Quote
OS250B03P

OS250B03P

3

250 A

B1-B3

Add to Quote
OS315B03P

OS315B03P

3

315 A

B1-B4

Add to Quote
OS400B03P

OS400B03P

3

400 A

B1-B4

Add to Quote
OS630B03P

OS630B03P

3

630 A

C1-C2

Add to Quote
OS800B03P

OS800B03P

3

800 A

C1-C3

Add to Quote
OS1250B03P

OS1250B03P

3

1250 A

D1

Add to Quote
OESA32G1N

OESA32G1N

TPN Neutral in mechanism (Wrapped)

32 A

A2

Add to Quote
OESA63G1N

OESA63G1N

TPN Neutral in mechanism (Wrapped)

63 A

A3

Add to Quote
OESA100G1N

OESA100G1N

TPN Neutral in mechanism (Wrapped)

100 A

A4

Add to Quote
OESA125G1N

OESA125G1N

TPN Neutral in mechanism (Wrapped)

125 A

A4

Add to Quote
OESA160B3N

OESA160B3N

TPN Neutral in mechanism (Wrapped)

160 A

B2

Add to Quote
OS200B03N3P

OS200B03N3P

TPN Neutral in mechanism (Wrapped)

200 A

B1-B2

Add to Quote
OS250B03N3P

OS250B03N3P

TPN Neutral in mechanism (Wrapped)

250 A

B1-B3

Add to Quote
OS315B03N3P

OS315B03N3P

TPN Neutral in mechanism (Wrapped)

315 A

B1-B4

Add to Quote
OS400B03N3P

OS400B03N3P

TPN Neutral in mechanism (Wrapped)

400 A

B1-B4

Add to Quote
OS630B03N3P

OS630B03N3P

TPN Neutral in mechanism (Wrapped)

630 A

C1-C2

Add to Quote
OS800B03N3P

OS800B03N3P

TPN Neutral in mechanism (Wrapped)

800 A

C1-C3

Add to Quote
OS1250B03N3P

OS1250B03N3P

TPN Neutral in mechanism (Wrapped)

1250 A

D1

Add to Quote
OESA32G4

OESA32G4

4 (Solid Neutral)

32 A

A2

Add to Quote
OESA63G4

OESA63G4

4 (Solid Neutral)

63 A

A3

Add to Quote
OESA100G4

OESA100G4

4 (Solid Neutral)

100 A

A4

Add to Quote
OESA125G4

OESA125G4

4 (Solid Neutral)

125 A

A4

Add to Quote
OESA160B4

OESA160B4

4 (Solid Neutral)

160 A

B2

Add to Quote
OS200B04N2P

OS200B04N2P

4 (Solid Neutral)

200 A

B1-B2

Add to Quote
OS250B04N2P

OS250B04N2P

4 (Solid Neutral)

250 A

B1-B3

Add to Quote
OS315B04N2P

OS315B04N2P

4 (Solid Neutral)

315 A

B1-B4

Add to Quote
OS400B04N2P

OS400B04N2P

4 (Solid Neutral)

400 A

B1-B4

Add to Quote
OS630B04N2P

OS630B04N2P

4 (Solid Neutral)

630 A

C1-C2

Add to Quote
OS800B04N2P

OS800B04N2P

4 (Solid Neutral)

800 A

C1-C3

Add to Quote
OS1250B04N2P

OS1250B04N2P

4 (Solid Neutral)

1250 A

D1

Add to Quote

Additional information for OESA/OS switch disconnector fuse, BS-type

ABB OESA/OS switch disconnector fuse, BS-type FAQ 1. What is the advantage of BS-type switch fuse units? BS-type units are designed for BS standard fuse links, offering dependable short-circuit protection and compatibility with specific industrial panel requirements. 2. What current ratings are available? The OESA/OS BS-type range covers 32A to 800A, suitable for feeder circuits and main incomer isolation. 3. Are these suitable for AC-23A load switching? Yes. These switch fuse units are rated for AC-23A applications, ensuring reliable switching of motor and inductive loads. 4. Can these be used in industrial MCC panels? Yes. They are widely installed in MCC panels, distribution boards and infrastructure projects requiring safe isolation. 5. Do you support bulk supply and project pricing? Yes. As an Authorized ABB Distributor in Coimbatore, we provide bulk inventory, competitive project pricing and fast dispatch across India.

Find Related

Enquire Now